Description
- Voltage measurement: 550 VAC / 800 VDC
- Continuity at 200 mA,
- Resistance from 1 to 99.99 k?
- Insulation: 250V, 500V or 1,000 V test voltage – Zs (Z L-PE) loop without tripping: 1 to 2,000 ?, calculation of Ik
- Zs (Z L-PE) high-current loop with tripping and Zi (Z L-N or Z L-L), from 0.1 to 400 ?, calculation of Ik
- Type AC & A RCDs: 30mA, 100mA, 300 mA, 500 mA, 650 mA
- RCD in pulse mode: tripping time
- RCD in ramp mode (30 mA): tripping current
- Phase rotation: 45 to 550V; 45 to 65 Hz
- Frequency measurement: 30 Hz to 999.9 Hz
- Insulation: additional 1,000 V test voltage
- 3P earth (stakes): up to 2,000 ?
- Automatic RCD test sequence: no trip-pulse-ramp
- Automatic test sequence: Loop-RCD-M?
- Data storage: 30 sites with 99 tests each by pressing the MEM key or using the optional remote-control probe
- Power supply by rechargeable batteries with built-in charger
- Recharging possible via the mains, USB socket or vehicle cigarette lighter socket
- Bluetooth communication
- Automatic recognition of the optional MN73A external clamp